Knowledge Center / Optical Knowledge / Optical Module Form Factors: SFP to OSFP Quick Reference

Optical Module Form Factors: SFP to OSFP Quick Reference

SFP, SFP+, SFP28, QSFP28, QSFP-DD and OSFP explained — lane rates, typical speeds and how to read a port.

Updated October 2026 · AltoChip team · General reference — project specifics are confirmed in each quotation.

Read the port first

The cage on your switch or NIC decides the form factor. A module must physically fit the cage and run at a rate the port supports. Port speed and cage type are on the device datasheet or front-panel label — that is the first line of every optical RFQ.

Quick reference

Form factorElectrical lanes × rateTypical speedCommon use
SFP1 × 1G1GManagement, legacy access
SFP+1 × 10G10GServer NICs, access switches
SFP281 × 25G25GServer-to-leaf
QSFP+4 × 10G40GLegacy aggregation
QSFP284 × 25G (or 2 × 50G PAM4)100GLeaf-spine, server uplinks
QSFP564 × 50G PAM4200GHPC / AI NICs
QSFP-DD8 × 50G or 8 × 100G PAM4400G / 800GSpine, AI fabrics
OSFP8 × 50G or 8 × 100G PAM4400G / 800GAI fabrics, high-power optics

Typical values for orientation; the device datasheet is authoritative.

Backward fit is not automatic

Some cages accept smaller modules (for example SFP+ in an SFP28 port, or QSFP28 in a QSFP-DD port), but the port must be configured for the lower speed and the platform must support it. QSFP-DD and OSFP are not interchangeable with each other. Confirm with the device documentation before mixing generations.

Planning an optical project?

Request a Project Quote All optical topics